- Contact Person : Ms. Wang Maria
- Company Name : Hangzhou Development Center of Water Treatment Technology Co., Ltd.
- Tel : 0086-571-88935359
- Fax : 0086-571-88935400
- Address : Zhejiang,Hangzhou,No. 50 Wenyi West Road
- Country/Region : China
- Zip : 310012
Related Product Searches:RO membrane (equivalent to filmtec BW30-400),High Quality,membrane, RO membrane
BDXB-400 series is equal to filmtec BW30-400 RO membrane, it is applicable to the water which contains less than 5000ppm salt. It is used to produce pure water or ultra pure water in Electronics, Power, Petrochemical, Food, Beverage and Pharmacy.
| Model | BDX8040B-400 | |
Capability
| Materials | PA (polyamide) | |
Average Salt Rejection% | 99.5(99.0) | ||
Permeate Flow gpd(m3/d) | 10500(40) | ||
Error | ±15% | ||
Active Membrane Area ft2(m2) | 400 (37) | ||
Testing Conditions
| Standard Solution | 2000 ppm NaCl | |
Operating Pressure psi(MPa) | 225(1.55) | ||
Recovery Rate of Single Membrane Element | 15% | ||
Temperature deg C | 25 | ||
PH Value of Solution | 6.5-8.5 | ||
Test Time | Run for 30 minutes | ||
Limiting Conditions
| Max. Feedwater Temperature deg C | 45 | |
Max. Operating Pressure psi(MPa) | 600(4.12) | ||
Max. Feedwater Flow gpm(m3/h) | 75(17.0) | ||
Max. SDI of Feedwater | 5 | ||
Max. NTU of Feedwater | 1 | ||
Concentration of Free Chlorine --- ppm | < 0.1 | ||
PH Value Range of Feedwater as Continuous Operation | 2-11 | ||
PH Value Range of Feedwater as Chemical Cleaning | 1-12 | ||
Max. Pressure Difference of Single Membrane Element psi(MPa) | 13(0.09) | ||
The minimal proportion of single membrane element's conc. press to perm. Flow | 5 : 1 |
RO membrane (equivalent to filmtec BW30-400)